Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
1.
Acta odontol. latinoam ; 36(2): 112-119, Aug. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513554

RESUMO

ABSTRACT Advanced Polymerization System (APS) technology in a commercial composite resin enables reduction of the concentration of camphorquinone without altering composite physicochemical properties. Aim: The aim of this study was to evaluate the degree of conversion and mechanical properties of a commercial composite with an advanced polymerization system (APS) and compare it to other composites that do not use this system. Materials and Method: Five groups were analyzed. Group 1 (VT: Vittra APS - FGM); G2 (AU: Aura - SDI); G3 (ES: Quick Sigma Stelite - TOKOYAMA); G4 (FZ: Filtek Z350 XT - 3M ESPE); G5 (OP: Opallis -FGM). Degree of conversion (DC, n=3) was analyzed immediately and after 24h by analysis with FTIR spectroscopy. For Knoop hardness (KHN, n=3), 5 indentations were made at the top and bottom of specimens 2 mm thick. Flexural strength (FS, n=10) was determined by the three-point method in a universal testing machine. Polymerization stress (PS) was determined by light-curing the material (1.0 mm high) between polymethylmethacrylate rods in a universal testing machine. Light curing was performed with a Valo Cordless LED (1,000 mW/cm2 x 20 s: 20J). The results were analyzed using ANOVA and complemented by Tukey's test (α=0.05). Results: The highest DC values (immediate and 24h after) were observed for VT and OP resins, followed by FZ, AU and ES. FZ (top and bottom) had the highest KHN values, similar to VT top. AU, ES, OP and VT had statistically different KHN between their top and bottom surfaces. The highest RF values were observed for FZ, followed by OP/VT, ES and AU. The highest TP values were observed for FZ, OP and VT. Conclusion: The Vittra APS resin with a new polymerization system presents satisfactory performance for the parameters evaluated.


RESUMO A tecnologia Advanced Polymerization System (APS) presente em uma resina composta comercial permite reduzir a concentração de canforoquinona sem alterar as propriedades físico-químicas do compósito. Objetivo: o objetivo deste estudo foi avaliar o grau de conversão e as propriedades mecânicas de um compósito comercial com sistema avançado de polimerização (SAP) e comparálo com outros compósitos que não utilizam esse sistema. Materiais e Método: cinco grupos foram analisados. Grupo 1 (VT: Vittra APS - FGM); G2 (AU: Aura - SDI); G3 (ES: Quick Sigma Stelite - TOKOYAMA); G4 (FZ: Filtek Z350 XT - 3M ESPE); G5 (OP: Opallis -FGM). O grau de conversão (GC, n=3) foi analisado imediatamente e após 24h através da análise com espectroscopia FTIR; para dureza Knoop (DK, n=3), foram feitas 5 indentações no topo e na base de corpos de prova de 2 mm de espessura; para determinar a resistência à flexão (RF, n=10), o método de três pontos foi realizado em uma máquina universal de ensaios; a tensão de polimerização (TP) foi determinada pela fotopolimerização do material (1,0 mm de altura) entre hastes de polimetilmetacrilato em uma máquina de teste universal. A fotopolimerização foi realizada com um Valo Cordless LED (1.000 mW/cm2 x 20 s: 20J). Os resultados foram analisados por ANOVA e complementados pelo teste de Tukey (α=0,05). Resultados: os maiores valores de GC (imediato e 24h após) foram observados para as resinas VT e OP, seguidas de FZ, AU e ES. A resina FZ (superior e inferior) apresentou os maiores valores de DK, semelhante ao VT superior. As resinas AU, ES, OP e VT apresentaram DK estatisticamente diferente entre suas superfícies de topo e base. Os maiores valores de RF foram observados para FZ, seguido de OP/VT, ES e AU. Os maiores valores de TP foram observados para FZ, OP e VT. Conclusão: com base nos resultados, pode-se concluir que a resina Vittra APS com um novo sistema de polimerização apresenta desempenho satisfatório para os parâmetros avaliados.

2.
RFO UPF ; 27(1)08 ago. 2023. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1511047

RESUMO

Objetivo: avaliar in vitro o polimento sobre resina acrílica quimicamente ativada (RAQA), por meio da rugosidade de superfície (Ra). Materiais e Método: Foram confeccionadas 40 amostras de RAQA, com dimensões de 10 a 10 x 2 mm, e foram divididas em quatro grupos (n=10): ausência do acabamento (AA); Ausência de polimento (AP); Polimento químico (PQ); Polimento com borrachas siliconadas + Escovas (PM). Os espécimes foram avaliados no quanto a rugosidade média (Ra) antes e após o envelhecimento em água destilada em uma estufa por 60 dias. Três medições de Ra (µm), na horizontal foram realizadas e calculada uma média para cada espécime. Os dados foram analisados de forma descritiva e inferencial, ANOVA de medidas repetidas e teste de Tukey com nível de significância de 5%. Resultados: Inicialmente, o grupo AA teve os menores valores de Ra e o grupo AP os maiores valores de rugosidade, com média e desvio padrão respectivamente 0,17 (±0,11) e 0,52 (±0,10). Após o envelhecimento, o grupo AA teve as menores médias e o grupo PQ os maiores valores de Ra, sendo 0,38 (±0,20) e 1,33 (±0,32), respectivamente. Os resultados evidenciaram diferença estatística significante quando as amostras foram submetidas ao acabamento com brocas. Conclusão: A RAQA necessita de polimento após acabamento com brocas, uma vez que a ausência de polimento comprometerá a lisura de superfície do material.(AU)


Objective: to evaluate in vitro polishing on chemically activated acrylic resin (RAQA), using surface roughness (Ra). Materials and Method: 40 RAQA samples were made, measuring 10 to 10 x 2 mm, and divided into four groups (n=10): absence of finishing (AA); Lack of polishing (AP); Chemical polishing (PQ); Polishing with silicone rubbers + Brushes (PM). The specimens were evaluated for their average roughness (Ra) before and after aging in distilled water in an oven for 60 days. Three horizontal Ra (µm) measurements were taken and an average was calculated for each specimen. Data were analyzed descriptively and inferentially, using repeated measures ANOVA and Tukey test with a significance level of 5%. Results: Initially, the AA group had the lowest Ra values and the AP group the highest roughness values, with mean and standard deviation respectively 0.17 (±0.11) and 0.52 (±0.10). After aging, the AA group had the lowest averages and the PQ group the highest Ra values, being 0.38 (±0.20) and 1.33 (±0.32), respectively. The results showed a statistically significant difference when the samples were finished with drills. Conclusion: RAQA requires polishing after finishing with drills, as the lack of polishing will compromise the surface smoothness of the material.(AU)


Assuntos
Resinas Acrílicas/química , Polimento Dentário/métodos , Valores de Referência , Elastômeros de Silicone , Propriedades de Superfície , Fatores de Tempo , Análise de Variância , Estudo de Avaliação
3.
Natal; s.n; 20 jul. 2023. 46 p. ilus, tab, graf.
Tese em Português | BBO - Odontologia | ID: biblio-1532134

RESUMO

Objetivo: Avaliar a profundidade de polimerização em diferentes espessuras da resina composta Tetric® N-Flow Bulk Fill com adição de xilitol em diferentes concentrações. Metodologia: A resina Tetric® N-Flow Bulk Fill foi misturada às concentrações do xilitol (0% [Controle], 2,5% e 5% g/g) por espatulação manual durante 1 min em uma câmara escura. Amostras cilíndricas foram confeccionadas em moldes de polimetilmetacrilato de 5 mm de diâmetro x 1 mm, 2 mm, 3 mm e 4 mm de espessura nas concentrações de xilitol propostas totalizando 12 grupos (n=3), fotoativadas por 10 s e armazenadas a 37º C por 24 h. Os espécimes foram submetidos ao teste de microdureza Vickers, sendo a profundidade de polimerização obtida por meio da razão base/topo. Foram utilizados testes não paramétricos de Kruskal Wallis para comparação das diferentes espessuras na mesma concentração e das diferentes concentrações na mesma espessura (p<0,05) através do software BioEstat 5.3. Resultados: Não houve diferença estatisticamente significativa entre as diferentes espessuras na mesma concentração, bem como entre as diferentes concentrações na mesma espessura (p=1,000). Todos os espécimes apresentaram profundidade de polimerização adequada (razão de dureza ≥80%), com exceção das amostras com 4 mm de espessura contendo 2,5 e 5% de xilitol, que apresentaram razão de dureza média de 79% e 74%, respectivamente. Conclusão: Nas condições deste estudo, pode-se concluir que a adição de xilitol a uma resina bulk fill fluida pode afetar a profundidade de polimerização em 4 mm (AU).


Objective: To evaluate the depth of cure at different thicknesses of the Tetric® NFlow Bulk Fill composite resin with the addition of xylitol at different concentrations. Materials and Methods: The Tetric™ N-Flow Bulk Fill resin was mixed with xylitol concentrations (0% [Control], 2.5%, and 5% g/g) by manual spatulation for 1 minute in a portable darkroom. Cylindrical samples were prepared in polymethyl methacrylate molds with diameters of 5 mm and thicknesses of 1 mm, 2 mm, 3 mm, and 4 mm at the proposed xylitol concentrations, totaling 12 groups (n=3), photoactivated for 10 seconds, and stored at 37°C for 24 hours. The specimens were subjected to Vickers microhardness testing, and the depth of cure was obtained by calculating the base/top ratio. Non-parametric Kruskal-Wallis tests were used to compare different thicknesses at the same concentration and different concentrations at the same thickness (p<0,05) using BioEstat 5.3 software. Results: There was no statistically significant difference between different thicknesses at the same concentration, as well as between different concentrations at the same thickness (p=1,000). All specimens exhibited adequate depth of cure (hardness ratio ≥80%), except for the samples with 4 mm thickness containing 2.5% and 5% xylitol, which showed average hardness ratios of 79% and 74%, respectively. Conclusion: Under the conditions of this study, it can be concluded that the addition of xylitol to a fluid bulk fill resin can affect the depth of cure at 4 mm (AU).


Assuntos
Teste de Materiais , Estatísticas não Paramétricas
4.
RGO (Porto Alegre) ; 71: e20230057, 2023. tab
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1521435

RESUMO

ABSTRACT Objective: To evaluate the effect of thermocycling on the Knoop internal microhardness of high- and low viscosity bulk fill resins applied in Class I cavities. Methods: Thirty third molars with Class I cavity preparations were randomly divided into 3 groups according to the restorative system: nanoparticulated composite resin (Filtek™ Z350 XT 3M ESPE) (oblique increments of 2mm); low viscosity bulk fill resin (Filtek™ Bulk fill Flow, 3M ESPE) (3mm increments covered with a 1-mm layer of nanoparticulated resin); high viscosity bulk fill resin (Filtek™ Bulk fill, 3M ESPE) (single 4-mm increment). After 24h, half of samples was submitted to thermocycling (1,000 cycles). All samples (n=5) were sectioned in half to measure the internal microhardness at bottom and top of restoration. Results: Analysis of variance indicated that, for nanoparticulated composite resin, without thermocycling, the microhardness at the top was statistically lower than at the bottom. After thermocycling, there was no difference in microhardness between the top and the bottom. For low viscosity bulk fill resin, without thermocycling, there was no significant difference in microhardness means between the top and the bottom. After thermocycling, significantly higher microhardness was found at the top than at the bottom (p <0.05). For high viscosity bulk fill resin there was no significant difference between the microhardness values at the top and bottom, regardless of thermocycling (p> 0.05). In all composite resins, an increase in microhardness was observed after thermocycling (p <0.05). Conclusion: Thermocycling increased the internal microhardness of resin restorations, and, for the low viscosity bulk fill resin, the microhardness at the top was higher than at the bottom after thermocycling.


RESUMO Objetivo: Avaliar o efeito da termociclagem na microdureza Knoop interna de resinas bulk fill de alta e baixa viscosidade aplicadas em cavidades classe I. Métodos: Trinta terceiros molares com cavidades Classe I foram divididos aleatoriamente em três grupos de acordo com o sistema restaurador: Resina composta nanoparticulada (Filtek™ Z350 XT 3M ESPE) (incrementos oblíquos de 2mm); resina bulk fill de baixa viscosidade (Filtek™ Bulk fill Flow, 3M ESPE) (incremento de 3mm mais 1mm de resina nanoparticulada); resina bulk fill de alta viscosidade (Filtek ™ Bulk fill, 3M ESPE) (único incremento de 4mm). Após 24h, metade das amostras foi submetida a termociclagem (1.000 ciclos). Todas as amostras (n=5) foram seccionadas ao meio para mensuração da microdureza interna na base e topo da restauração. Resultados: Análise de variância indicou que, para a resina composta nanoparticulada e antes da termociclagem, a microdureza no topo foi estatisticamente inferior do que na base (p<0,05). Após a termociclagem, não houve diferença entre topo e base. Já para a resina bulk fill de baixa viscosidade, antes da termociclagem, não se constatou diferença significativa nos valores de microdureza entre topo e base. Após termociclagem, valores significativamente mais elevados de microdureza foram encontrados no topo do que na base (p<0,05). Para resina bulk fill de alta viscosidade, não houve diferença significativa na microdureza entre topo e base, realizando-se ou não termociclagem (p>0,05). Em todas as resinas compostas foi verificado aumento de microdureza após termociclagem (p<0,05). Conclusão: A termociclagem aumentou a microdureza para todas as resinas compostas, sendo que para a resina bulk fill de baixa viscosidade a microdureza no topo foi maior do que na base após termociclagem.

5.
Braz. dent. sci ; 26(2): 1-11, 2023. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1425563

RESUMO

Objective: The present study aims to evaluate the color stability and degree of conversion of amine-free dual cured resin cement compared to light cured and amine-containing dual cured resin cements used with two different translucencies of thin esthetic restorations. Material and Methods: A total of 120 specimens were prepared for color stability testing (n=60). The specimens were divided into three main groups according to the resin cement type. Group 1: amine-free dual cured, Group 2: light cured, Group 3: amine-containing dual cured. Each group was further subdivided according to the ceramic translucency into two subgroups: high and low translucency. Color stability was assessed by a spectrophotometer before and after thermal aging. For the degree of conversion assessment (n=60), Fourier transform infrared spectroscopy was used at three different time intervals. Statistical analysis was performed using multi-factorial ANOVA, followed by one-way ANOVA with Bonferroni correction. Results: Amine-containing resin cement showed significantly higher ΔEab and ΔE00in both translucencies (4.5±0.3, 3.5±0.3 respectively for high translucency ceramic and 3.8±0.4, 3.0±0.3 respectively for low translucency) than the other tested cements (p<0.001). The highest degree of conversion (DC) was shown after 2 weeks by the amine-free dual cured resin cement (86.27±0.74). Conclusion: Amine-free dual cured resin cement can be an alternative to light cured one for cementation of thin veneers since it showed comparable color stability and high degree of conversion (AU)


Objetivo: O presente estudo tem como objetivo avaliar a estabilidade de cor e o grau de conversão do cimento resinoso dual sem amina em comparação com cimentos resinosos fotopolimerizáveis contendo amina usados com duas translucidezes diferentes em restaurações estéticas definitivas. Material e Métodos: Um total de 120 espécimes foram preparados para teste de estabilidade de cor (n=60). Os espécimes foram divididos em três grupos principais de acordo com o tipo de cimento resinoso. Grupo 1: polimerização dupla sem amina, Grupo 2: fotopolimerização, Grupo 3: polimerização dupla contendo amina. Cada grupo foi ainda subdividido de acordo com a translucidez da cerâmica em dois subgrupos: alta e baixa translucidez. A estabilidade da cor foi avaliada por um espectrofotômetro antes e após o envelhecimento térmico. Para a avaliação do grau de conversão (n=60), a espectroscopia de infravermelho com transformada de Fourier foi usada em três intervalos de tempo diferentes. A análise estatística foi realizada usando ANOVA multifatorial, seguida de ANOVA um faot com correção de Bonferroni. Resultados: O cimento resinoso contendo amina apresentou ΔEab e ΔE00 significativamente maiores em ambas as translucidezes (4,5±0,3, 3,5±0,3 respectivamente para cerâmica de alta translucidez e 3,8±0,4, 3,0±0,3 respectivamente para baixa translucidez) do que os outros cimentos testados (p< 0,001). O maior grau de conversão (DC) foi mostrado após 2 semanas pelo cimento resinoso dual sem amina (86,27±0,74). Conclusão: O cimento resinoso dual sem amina pode ser uma alternativa ao cimento polimerizável na restauração de facetas finas, uma vez que apresentou estabilidade de cor comparável e alto grau de conversão. (AU).


Assuntos
Cor , Cimentos de Resina , Polimerização , Lítio
6.
Araçatuba; s.n; 2022. 54 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1435699

RESUMO

O objetivo desse trabalho foi avaliar a influência de diferentes graus de opacidade e espessuras do dissilicato de lítio no grau de conversão de dois cimentos resinosos e na resistência de união dos mesmos à cerâmica. Duzentos e quarenta amostras cerâmicas de dissilicato de lítio (6x6 mm) foram obtidos a partir de blocos de IPS E-max CAD (Ivoclar Vivadent, Schaan, Liechtensten), nas opacidades HT (alta translucidez), LT (baixa translucidez) e MO (média opacidade), nas espessuras de 0,3 mm, 0,7 mm, 1,2mm, 1,7 mm, 2,0 mm. Para as análises do grau de conversão (n=9) e resistência de união (n=8) foram utilizados um cimento de ativação física (Variolink Esthetic LC) e um cimento dual (Multilink N). Para análise do grau de conversão, as amostras de cimento foram fotoativadas sob as amostras de cerâmica e levadas a um espectrômetro Raman confocal. Para o teste de resistência de união foram confeccionados cilindros de cimento resinoso sobre as amostras cerâmicas e submetidos ao ensaio de microcisalhamento. Os resultados mostraram que o aumento das espessuras causou diminuição no grau de conversão dos dois cimentos em todas as condições estudadas, porém só influenciou negativamente a resistência de união do cimento Variolink Esthetic LC quando unido à cerâmica na opacidade MO. Na comparação entre as opacidades, de maneira geral, a cerâmica de maior translucidez HT apresentou maiores valores de grau de conversão em comparação às outras opacidades. Já para resistência de união, em algumas espessuras as cerâmicas LT e MO apresentaram os maiores valores. O cimento dual Multilink N apresentou os maiores valores nas duas análises comparado ao cimento fotoativado Variolink Esthetic LC. Portanto, o aumento da espessura e da opacidade do material cerâmico podem promover uma diminuição no grau de conversão do cimento. A resistência de união também sofre uma diminuição com o aumento da espessura de cerâmicas mais opacas. No entanto, a maior translucidez do material não garante valores mais altos dessa mesma propriedade(AU)


This research aims to evaluate the influence of different degrees of opacity and thicknesses of lithium disilicate on the degree of conversion of two resin cements and on their bond strength to the ceramic. Two hundred and forty lithium disilicate ceramic samples (6x6 mm) were obtained from IPS E-max CAD (Ivoclar Vivadent, Schaan, Liechtensten), in HT, LT and MO opacities, with thicknesses of 0.3 mm, 0.7 mm, 1.2 mm, 1.7 mm, 2.0 mm. For degree of conversion (n=9) and bond strength analysis (n=8) a light cured (Variolink Esthetic LC) and a dual cured resin cement (Multilink N) were used. To analyze the degree of conversion, the cement samples were light cured under the ceramic samples and taken to a confocal Raman spectrometer. For the bond strength test, resin cement cylinders were made on the ceramic samples that were later subjected to a microshear. The results showed that the increase in thickness caused a decrease on degree of conversion of both cements in all the conditions studied, but it only had an influence on bond strength of Variolink LC cement for MO ceramic. Comparing the opacities, for the degree of conversion, the most translucent ceramics had higher conversion values compared to the less translucent ones in some thicknesses. As for bond strength, in some thicknesses the LT and MO ceramics showed the highest values. The dual cement Multilink showed the highest values of conversion degree and bond strength compared to Variolink Esthetic LC light-cured cement. The Multilink dual cement showed the highest values in both analyzes compared to the Variolink LC light-cured cement. Therefore, increasing the thickness and opacity of the ceramic material can promote a decrease in the degree of cement conversion. The bond strength also suffers a decrease with increasing thickness of more opaque ceramics and the greater translucency of the material does not guarantee higher values of this same property(AU)


Assuntos
Cimentos de Resina , Porcelana Dentária , Cerâmica , Materiais Dentários , Polimerização
7.
Rev. odontol. UNESP (Online) ; 51: e20220043, 2022. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1424239

RESUMO

Introdução: a inovação dos métodos de fotopolimerização foi proposta na tentativa de diminuir o estresse de contração de polimerização das resinas compostas e proporcionar maior conforto ao paciente, reduzindo o tempo de atendimento odontológico. Objetivo: avaliar a microdureza de duas resinas compostas nanoparticuladas submetidas a diferentes técnicas de polimerização. Material e método: quarenta espécimes foram divididos em quatro grupos (n=10) da seguinte forma: Filtek Z350 XT® + técnica imediata (GI); Filtek One Bulkfill® + técnica imediata (GII); Filtek Z350 XT® + técnica de pulso tardio (GIII); Filtek One Bulkfill® + técnica de pulso tardio (GIV). Após o armazenamento em água destilada à temperatura ambiente, os corpos de prova foram direcionados para a medição de microdureza. Utilizou-se teste T para comparação de técnicas e teste Two-Way ANOVA para calcular os efeitos das resinas compostas, técnicas de polimerização e interações referentes à variável dependente (p ≤0,05). Resultado: a resina Filtek Z350 XT® apresentou maior dureza na técnica imediata (GI - 312,45 ± 64,37) e pulso tardio (GIII - 244,50 ± 75,63) comparado à resina Filtek One Bulkfill®, em ambas as técnicas. Observaram-se maiores valores de dureza referentes à técnica imediata, com diferença estatística significativa em relação à resina testada (p = 0,04 - Filtek Z350 XT®; p = 0,03 - Filtek One Bulkfill®). Ambos os fatores isolados (resina e técnicas) apresentaram efeito nos valores de microdureza (p = 0,02 e p < 0,01, respectivamente). Conclusão: a técnica convencional demonstrou atingir maiores valores de dureza quando comparada à técnica de polimerização alternativa.


Introduction: the innovation of photopolymerization methods was proposed in an attempt to reduce the polymerization shrinkage stress of composite resins and also provide more comfort to patient reducing the chair time. The aim of this in vitro study was to assess the microhardness of two nanofilled composite resins subject to different curing techniques. Objective: assess the microhardness of two nanofilled composite resins subject to different curing techniques. Material and method: forty specimens were divided into four groups (N=10) as follows: Filtek Z350 XT® + immediate technique (GI); Filtek One Bulkfill® + immediate technique (GII); Filtek Z350 XT® + delayed pulse technique (GIII); Filtek One Bulkfill® + delayed pulse technique (GIV). After storage in distilled water at room temperature the specimens were assessed for microhardness measurement. T-test was used for comparison of techniques and two-way ANOVA used to calculate the effects of composite resins, curing techniques and their interactions on dependent variable (p set at 0.05). Result: Filtek Z350 XT® resin presented greater hardness on immediate technique (GI - 312,45 ± 64.37) and delayed pulse (GIII - 244,50 ± 75.63) compared to Filtek One Bulkfill® under both techniques. Overall, it was observed greater hardness values under immediate technique with a significant statistical difference apart of tested resin (p = 0.04 - Filtek Z350 XT®; p = 0.03 - Filtek One Bulkfill®). Both isolated factors (resin and techniques) presented effect on microhardness values (p = 0.02 and p < 0.01, respectively). Conclusion: the conventional technique demonstrated to reach higher hardness values when compared to the alternative polymerization technique


Assuntos
Técnicas In Vitro , Análise de Variância , Resinas Compostas , Cura Luminosa de Adesivos Dentários , Testes de Dureza
8.
Braz. dent. sci ; 25(1): 1-8, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1361498

RESUMO

Objective: To evaluate the influence of the incorporation of a polymerization catalyst to a light-cured pulp capping material on mechanical behavior and physicochemical characteristics. Material and Methods: Different percentages (2 wt%, and 4 wt%) of diphenyliodonium hexafluorophosphate (DPI) were incorporated into the Ultra-Blend Plus, a resin-modified calcium-based cement. The material without incorporation of DPI (0 wt%) served as control. Degree of Conversion (DC), Flexural Strength (FS), Elastic Modulus (EM), Water Sorption (WSp), Solubility (Sl), and pH of eluate at 24-h, 72-h, and 7-day storage times were measured. One-way ANOVA/Tukey posthoc tests were used to analyze the data (p <0.05). Results: For DC, FS, and EM, materials with different % of DPI showed statistically significant differences, so that 0% provided the lowest values and 2% the highest values. Materials with 0% and 2% of DPI provided statistically the lowest WSp, whilst material with 0% of DPI showed statistically the highest Sl. Conclusion: All materials provided statistically similar pH to eluates regardless of storage time, although only materials with DPI at 2% and 4% maintained pH of eluates statistically similar from 72 h to 7 days storage times.(AU)


Objetivo: avaliar a influência nas propriedades mecânicas e físico-químicas da incorporação de um catalisador de polimerização a um protetor pulpar fotoativável. Material e Métodos: foram adicionadas diferentes porcentagens em massa (2% e 4%) de hexafluorofosfato de difeniliodônio (DPI) ao Ultra-Blend Plus, um cimento à base de hidróxido de cálcio modificado por resina. O material sem a adição do DPI (0%) serviu como controle. Foram avaliados: Grau de Conversão (DC), Resistência Flexural (FS), Módulo de Elasticidade (EM), Sorção (WSp), Solubilidade (SI) e o pH do eluato nos tempos de 24h, 72h e 7 dias de armazenamento. ANOVA 1-way com pós-teste de Tukey (p <0.05). Foi utilizado para avaliar os resultados estatisticamente. Resultados: Os materiais com diferentes % de DPI apresentaram diferenças significativas para os testes de DC, FS e EM. A porcentagem em massa de 0% de DPI mostrou valores inferiores a todos os testados e os materiais com adição 2% apresentaram a melhor performance. Materiais com 0% e 2% de DPI apresentaram valores inferiores de WSp; a porcentagem de 0% proporcionou valores estatisticamente maiores para SI. Conclusão: Todos os materiais testados apresentaram pH semelhante nos eluatos independente do tempo de armazenamento, contudo, apenas os materiais com 2% e 4% mantiveram o pH dos eluatos estatisticamente similares nos tempos de estocagem de 72h a 7 dias.(AU)


Assuntos
Capeamento da Polpa Dentária , Módulo de Elasticidade , Polimerização , Solubilidade
9.
Rev. ABENO ; 21(1): 1065, dez. 2021. tab
Artigo em Português | BBO - Odontologia | ID: biblio-1371228

RESUMO

O sucesso clínico de materiais resinosos é dependente de uma adequada polimerização. Diversos materiais fotoativados são utilizados frequentemente nas clínicas-escola de Odontologia. O objetivo desse estudo foi avaliar o nível de conhecimento dos acadêmicos do 10º período de Odontologia do Centro Universitário Maurício de Nassau, Recife/PE,sobre fotopolimerização, por meio de questionário. Os dados foram tabulados e analisados por meio de estatísticas descritivas, teste Qui-quadrado de Pearson e teste Exato de Fischer, com nível de significância de 5% (p<0,05). Os resultados demonstram que 83,8%dos estudantesnão possuem fotopolimerizador, 72,9% não conhecem a potência do aparelho, 56,2% não sabem qual é a potência mínima ideal e apenas 8,5% sabem o nome do aparelho aferidor da irradiância / potência. Além disso, 48,5% não sabem o comprimento de onda ideal para fotoativação de resina composta e 69,2% desconhecemo tipo de aparelho que utilizam (monowaveou poliwave).Em relação ao tempo de fotopolimerização, 60,8% afirmaram utilizar20 segundos em resinas compostas convencionais e 38,5% utilizam por40 segundos em resinas compostas Bulk-fill. Embora 84,6% afirmem usar aparelhos fotopolimerizadores frequentemente, apenas 26,9% sabem a distância ideal da ponteira à restauração. Além disso, 51,5% relataram que fazem a limpeza e desinfecção com álcool 70GL e 45,4% usam barreira plástica. Nesse contexto, pode-se concluir que o nível do conhecimento dos acadêmicos em relação à fotopolimerização foi insatisfatório, exigindo uma abordagem e avaliaçãomais efetivaspara que os discentes tenham consciência da importância clínica deste procedimento e suas consequências (AU).


The clinical success of resin materials depends on adequate curing. Several light cured materials are frequently used in dental school clinics. This study aimed to assess the knowledge of students from the 10th period of Dentistry at Maurício de Nassau University Center, Recife/PE, about light curing, using a questionnaire. Data were tabulated and analyzed by descriptive statistics, Pearson chi-square test and Fisher exact test, at a significance level of 5% (p<0.05). The results show that 83.8% of studentsdo not have a light curing unit, 72.9% do not know the device power, 56.2% do not know the ideal minimum power and only 8.5% know the name of the device that measures the irradiance/power. Also, 48.5% do not know the ideal wavelength for light curing of composite resin and 69.2% do not know the type of device they use (monowave or polywave). Regarding the light curing time, 60.8% stated they used 20 seconds in conventional composite resins and 38.5% used 40 seconds in bulk-fill composite resins. Although 84.6% stated that they use light curing units frequently, only 26.9% know the ideal distance from the tip to the restoration. Additionally, 51.5% reported performing cleaning and disinfection with 70GL alcohol and 45.4% use a plastic barrier. In this context, it can be concluded that the knowledge of students regarding light curing was unsatisfactory, requiring a more effective approach and evaluation so that the students may be aware of the clinical importance of this procedure and its consequences (AU).


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Estudantes de Odontologia , Resinas Compostas/análise , Educação em Odontologia , Cura Luminosa de Adesivos Dentários , Polimerização , Brasil , Distribuição de Qui-Quadrado , Conhecimentos, Atitudes e Prática em Saúde , Inquéritos e Questionários/estatística & dados numéricos , Interpretação Estatística de Dados
10.
J. health sci. (Londrina) ; 23(3): 234-237, 20210920.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1292813

RESUMO

Bulk Fill resins are a class of resin composites widely used today and have low polymerization shrinkage. However, these materials need an appropriate light curing technique to have good physical and mechanical properties. The objective of this study was to evaluate the surface microhardness of Bulk Fill resins after their light-curing with two types of high- power light curing devices, using three techniques. 30 specimens were made with a nanoparticulate composite resin Opus Bulk Fill (FGM) and were divided into three groups according to the device and intensity of light curing: Group 1 - light curing with the Emitter B device (Schuster); Group 2 - light curing with the Valo device (Ultradent) at Standard power; and Group 3 - light curing with the Valo device at high power. Higher values of top surface microhardness were observed in Group 3 (microhardness = 53.6 µm), followed by Group 2 (microhardness = 52.1 µm) and Group 1 (microhardness = 33.1 µm), with p values <0.05. Therefore, the Valo light curing unit, in the two powers used, provided greater surface microhardness for the studied specimens. (AU)


Resinas Bulk Fill são uma classe de compósitos resinosos bastante utilizados atualmente e apresentam baixa contração de polimerização. Entretanto, esses materiais necessitam de uma adequada técnica de fotopolimerização para que apresentem boas propriedades físicas e mecânicas. O objetivo deste estudo foi avaliar a microdureza superficial de resinas Bulk Fill fotopolimerizadas com dois tipos de aparelhos fotopolimerizadores de alta potência, em três técnicas de utilização. Foram confeccionados 30 corpos de prova com uma resina composta nanoparticulada Opus Bulk Fill (FGM) e divididos em três grupos de acordo com o aparelho e intensidade de fotopolimerização: Grupo 1 ­ fotopolimerização com o aparelho Emitter B. (Schuster), Grupo 2 ­ fotopolimerização com o aparelho Valo (Ultradent) na potência Standard, Grupo 3 ­ fotopolimerização com o aparelho Valo em alta potência, posteriormente foi realizado o teste de microdureza de Vickers na região superficial de topo dos corpos de prova. Observou-se maiores valores de microdureza superficial de topo no Grupo 3 (microdureza= 53,6 µm), seguido pelo Grupo 2 (microdureza= 52,1 µm) e Grupo 1 (microdureza= 33,1 µm), com valores de p<0,05. Assim sendo, o aparelho fotopolimerizador Valo, nas duas potências utilizadas, forneceu maior microdureza superficial para os corpos de prova estudados. (AU)

11.
Dental press j. orthod. (Impr.) ; 26(1): e2119150, 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1154070

RESUMO

ABSTRACT Introduction: Third generation of LED light curing units might be used in short exposure periods for orthodontic brackets bonding. Objective: This study evaluated the effect of the different radiant exposure (RE) values: Manufacturers' instructions (MI), ½ MI, 1/4 MI and Turbo mode. Two third-generation LED curing units were used: VALO® and Bluephase 20i® . The degree of conversion (DC) and Vickers hardness (VHN) of an orthodontic composite (OC) (Transbond XT) under metallic (MB) or ceramic brackets (CB) were measured. Methods: OC was applied to the bracket base, which was then placed over an attenuated total reflectance (ATR) table coupled to an infrared light spectroscope, or to a glass surface for the VHN analysis. The specimens were light-cured and DC values were calculated. The VHN was obtained in a microhardness tester. The data were analyzed with 2-way ANOVA followed by Tukey's post-hoc test (pre-set α=0.05). Linear regression analysis evaluated the relationship between RE values and dependent variables. Results: CB allowed higher DC and VHN values than MB (p< 0.001). No significant difference was noted among groups when CB were used. For MB, MI groups showed the highest DC and VHN values. A significant, but weak relationship was found between delivered RE values and dependent variables. Conclusions: The decrease in RE values from third generation LED CU did not jeopardize the DC values when CB were used, but can compromise DC and VHN values when MB are used.


RESUMO Introdução: A terceira geração de LEDs fotopolimerizadores pode ser utilizada em curtos períodos de exposição para a colagem de braquetes ortodônticos. Objetivo: O presente estudo avaliou o efeito dos diferentes valores de irradiância (IR): instruções do fabricante (IF), ½ IF, » IF e modo Turbo. Dois fotopolimerizadores LED de terceira geração (VALO® e Bluephase20i®) foram utilizados. Foram mensurados o grau de conversão (GC) e a dureza Vickers (VHN) de um compósito ortodôntico (CO) (Transbond XT) sob braquetes metálicos (BM) ou cerâmicos (BC). Métodos: O compósito ortodôntico foi aplicado na base do braquete e foi posicionado sobre uma mesa de refletância total atenuada (ATR) acoplada a um espectroscópio de infravermelho ou a uma superfície de vidro para análise de VHN. As amostras foram fotopolimerizadas e os valores de GC foram calculados. O VHN foi obtido em um microdurômetro. Os dados foram analisados com ANOVA de 2 fatores seguida do teste post-hoc de Tukey (predefinido α = 0,05). A análise de regressão linear avaliou a relação entre os valores de IR e as variáveis dependentes. Resultados: BC permitiu valores maiores de GC e VHN do que BM (p<0,001). Nenhuma diferença significativa foi observada entre os grupos quando BC foi utilizado. Para BM, os grupos de IF mostraram os maiores valores de GC e VHN. Uma relação significativa, mas fraca, entre os valores de IR entregue e as variáveis dependentes foi encontrada. Conclusões: A diminuição dos valores de IR dos fotopolimerizadores LED de terceira geração não prejudicou os valores de GC quando BC foram utilizados, mas pode comprometer os valores de GC e VHN quando BM são utilizados.


Assuntos
Cerâmica , Braquetes Ortodônticos , Resinas Compostas , Luzes de Cura Dentária , Propriedades de Superfície , Teste de Materiais , Cimentos de Resina , Polimerização , Dureza
12.
Braz. dent. sci ; 24(1): 1-8, 2021. tab
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1145557

RESUMO

Objective: The purpose of this study was to evaluate the knowledge among dental students at King Khalid University, Jazan University, and Najran University in the kingdom of Saudi Arabia about when to repair or replace defective direct composite restoration. Materials and Methods: A questionnaire-based survey was formulated, pursuing the information about management (repair/replacement) of defective composite restorations and distributed among 200 dental students of three universities in the southern region of the kingdom of Saudi Arabia. The data were collected with the help of an online questionnaire. Data entry and the analysis were done using the statistical software package SPSS version 20.0. It was presented using descriptive statistics in the form of frequencies and percentages for qualitative variables, and range means and standard deviations for age, quantitative variable. Analytic statistics were done using Chi-Square tests (χ2) to test the significant difference between categorical variables. The level of significance, the p-value was 0.01(p<0.01). Results: The decision to choose between composite repair or replacement was influenced by whether this topic was taught to them at various undergraduate levels during Bachelor of Dental Surgery. The reason associated with the decision to repair defective composite restorations, 76% reported as cost-effective followed by Increased longevity (71%), the permanent filling (70%), patient's preference for repair (65%), and least time consuming (50%). 67% participants preferred significantly (p<0.001) repair due to secondary caries in the previously restored tooth with composite, followed by the small surface defect in a composite restoration (65%), risk of pulpal damage significantly (p<0.001) in a defective composite restoration (62.5%) and more invasive and destructive treatment option (35%). More than half of respondents 123 (61.5%) reported that they were not taught about composite repair during the Bachelor of Dental Surgery. Conclusion: It is suggested with the help of our study that didactic and clinical training components regarding composite repair should be seriously included in the teaching curriculum of dental institutions as it is in the best interest of the patient. Dental students should be provided with clinical training on this topic so that they can follow proper decision-making protocols available during repair or replacement of defective resin composite restorations. Other researches in the future can be carried out for refining the guidelines and techniques utilized for composite repair. (AU)


Objetivo: O objetivo deste estudo foi avaliar o conhecimento entre estudantes de odontologia da King Khalid University, Jazan University e Najran University, no reino da Arábia Saudita, sobre quando reparar ou substituir restaurações de resina composta direta defeituosas. Material e Métodos: Foi formulada uma pesquisa baseada em questionário, buscando informações sobre o manejo (reparo / substituição) de restaurações de resina composta e distribuída entre 200 estudantes de odontologia de três universidades da região sul do reino da Arábia Saudita. Os dados foram coletados com o auxílio de um questionário online. A entrada e análise dos dados foram feitas com o software estatístico SPSS versão 20.0. Foi apresentado por meio de estatística descritiva na forma de frequências e percentuais para as variáveis qualitativas, e amplitude de médias e desvios-padrão para a idade, variável quantitativa. A estatística analítica foi feita usando testes de qui-quadrado (χ2) para testar a diferença significativa entre as variáveis categóricas. Ao nível de significância, o valor de p foi de 0,01 (p <0,01). Resultados: A decisão de escolher entre o reparo ou substituição do compósito foi influenciada pelo fato de este tópico ter sido ensinado a eles em vários níveis de graduação durante o Bacharelado em Odontologia. O motivo associado à decisão de reparar restaurações de resina composta defeituosas, 76% relataram como custo-benefício seguido por maior longevidade (71%), restauração definitva (70%), preferência do paciente para reparo (65%) e menos demorado ( 50%). Sessenta e sete por cento dos participantes preferiram o reparo significativamente (p <0,001) devido a cárie secundária no dente previamente restaurado com resina composta, seguido pelo pequeno defeito de superfície em uma restauração composta (65%), risco de dano pulpar significativamente (p <0,001) em um restauração de resina composta com defeito (62,5%) e opção de tratamento mais invasiva e destrutiva (35%). Mais da metade dos entrevistados, 123 (61,5%) relataram que não foram ensinados sobre reparo de resina composta durante o Bacharelado em Odonotlogia. Conclusão: É sugerido com a ajuda de nosso estudo que os componentes do treinamento didático e clínico sobre reparo de resina composta devem ser seriamente incluídos no currículo de ensino de instituições odontológicas, pois é do interesse do paciente. Os estudantes de odontologia devem receber treinamento clínico sobre este tópico para que possam seguir os protocolos de tomada de decisão adequados disponíveis durante o reparo ou substituição de restaurações de resina composta com defeito. Outras pesquisas no futuro podem ser realizadas para refinar as diretrizes e técnicas utilizadas para reparo de resina (AU)


Assuntos
Humanos , Resinas Compostas , Cárie Dentária , Polimerização
13.
Araçatuba; s.n; 2021. 78 p. tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1510394

RESUMO

O objetivo deste estudo foi avaliar a influência do material cerâmico, cimento e tipo de substrato na qualidade estética de restaurações indiretas. A pesquisa científica foi dividida em duas partes. Na primeira análise, a alteração de cor e luminosidade de restaurações cerâmicas à base de dissilicato de lítio (e.max CAD), monossilicato de lítio (Celtra Duo) e cerâmica híbrida (Vita-Enamic CAD) foram analisadas quando sobrepostas em diferentes substratos (esmalte bovino, metal e zircônia), após a aplicação de pastas de prova "try-in" e após a cimentação com diferentes tipos de cimentos resinosos (RelyX Veneer, Variolink Esthetic LC e RelyX Ultimate). As análises foram realizadas em espectrofotômetro de reflexão UVVisivel (n=6). Os resultados mostraram que o tipo de substrato influenciou de maneira mais significante a estabilidade de cor e luminosidade das cerâmicas, independente da cor e tipo de material de cimentação. No segundo projeto, o objetivo foi avaliar a alteração cromática e a transmitância de diferentes restauraçoes cerâmicas: dissilicato de lítio (e.max CAD), monossilicato de lítio (Celtra Duo) e cerâmica híbrida (Vita-Enamic CAD) em oito diferentes espessuras (0,3mm à 2,0mm), com variação da potência do fotopolimerizador (1000mW/cm2 e 3200mW/cm2 ) e submetidos ao envelhecimento UV. As análises da alteração cromática foram realizadas em espectrofotômetro de reflexão UV-Visivel (n=8), enquanto que a análise da transmitância das cerâmicas foi realizada medindo-se a radiação de luz transmitida pelos diferentes materiais com um medidor de potência. Os resultados obtidos mostraram que os materiais cerâmicos estudados apresentam comportamentos diferentes quanto a estabilidade de cor das peças cimentadas. As diferentes espessuras influenciaram na cor do conjunto após o envelhecimento UV em todos os materiais estudados, sendo que a cerâmica de dissilicato de lítio e a cerâmica híbrida apresentaram influência nas espessuras mais delgadas. A transmitância dos materiais foi influenciada pela sua espessura e composição. A variação da potência do fotopolimerizador não influenciou na estabilidade de cor de todos os materiais analisados nas diferentes espessuras(AU)


The aim of this study was to evaluate the influence of ceramic material, resin cement and type of substrate in the aesthetic quality of indirect restorations. The research was divided into two chapters. In the first analysis, the color difference and luminosity of lithium disilicate (e.max CAD), zirconia-reinforced lithium silicate (Celtra Duo) and polymer infiltrated ceramic network (Vita Enamic CAD) were analyzed on different substrates (bovine enamel, metal and zirconia), after try-in pastes placed between the ceramics and substrates and after luting with different resin cements (RelyX Veneer, Variolink Esthetic LC e RelyX Ultimate) (n=6). The results showed that the type of substrate had more influence on the color stability and luminosity of ceramics, independent of the color and resin cement used. In the second study, the aim was to evaluate the color difference and transmittance of different ceramic restorations: lithium disilicate (e.max CAD), zirconia-reinforced lithium silicate (Celtra Duo) and polymer infiltrated ceramic network (Vita Enamic CAD) in eight thickness (0.3mm to 2.0mm), using light-emitting diode Valo Cordless (Standard and Xtra power modes) submitted to UV aging (n=8). The transmittance was done measuring the light transmitted through the materials with a power meter. The results showed that the ceramic materials showed different behavior in the color stability, especially for the thinner lithium disilicate and polymer infiltrated ceramic network materials. The transmittance was influenced by the thickness and composition of the materials. The variation in the power intensity of the lightemitting diode did not influence the color stability of the materials, independent of its thickness(AU)


Assuntos
Cor , Porcelana Dentária , Restauração Dentária Permanente , Estética Dentária , Polimerização
14.
Rio de Janeiro; s.n; 2021. 119 p. tab.
Tese em Português | BBO - Odontologia | ID: biblio-1399506

RESUMO

A presente pesquisa exploratória objetivou padronizar os processos de trabalho dos quatro Laboratórios Regionais de Prótese Dentária (LRPDS) que prestam apoio terapêutico à Saúde Bucal da Secretaria Municipal de Saúde (SMS) do Rio de Janeiro em atendimento ao requerimento de consultoria da Coordenação de Saúde Bucal (CSB) endereçado ao Mestrado Profissional em Clínica Odontológica da Universidade Federal do Rio de Janeiro (MPCOUFRJ) para revisão, avaliação, implementação e elaboração formulários estatísticos e de procedimentos operacionais padrão relacionados à especialidade de Prótese Dentária. Para o desenvolvimento do trabalho proposto os LRPDs foram visitados, proporcionando coletas e análises de dados do funcionamento das unidades; que foram apresentados e discutidos em reunião com a CSB. A partir dos dados coletados e analisados resultaram nos produtos técnicos e formulários necessários para a otimização dos processos de trabalho, e que foram apresentados em treinamento das equipes responsáveis pelos serviços de prótese dentária do Rio de Janeiro (RJ). Os levantamentos do estudo evidenciaram ausência de programa de gestão de resíduos de saúde por 3 das 4 unidades referidas, subnotificação e não utilização de códigos de faturamento de produção perante o Sistema Único de Saúde (SUS), ausência de padrão nos formulários de atendimento, das relatorias estatísticas, do controle de insumos e material permanente. Os problemas identificados por deste estudo, bem como sugestões para a melhoria, ampliação e democratização no acesso aos serviços de prótese dentária oferecidos à população foram levados ao conhecimento da Coordenação de Saúde Bucal (CSB), que considerou atendida a sua demanda. (AU)


The aim of this exploratory research was to standardize the work processes of the four Regional Dental Prosthesis Laboratories (LRPDS) that provide oral health therapeutic support to Rio de Janeiro City Health Department Council (SMS), in compliance with the consultancy requirement from the Oral Health Coordination (CSB) forwarded to the Federal University Professional Master's Degree Course in Clinical Dentistry of Rio de Janeiro (MPCO-UFRJ), to review, evaluate, improve and develop statistical forms and standard operating procedures related to the of Dental Prosthesis specialty. For the development of the proposed work, were visited the LRPDs, providing data collection and analysis of the operation of units; which were presented and discussed in a meeting with the CSB. From the data collected and analyzed resulted in the technical products and forms necessary for the optimization of work processes, and which were presented in training for the teams responsible for dental prosthesis services in Rio de Janeiro (RJ). The study surveys evidenced the lack of a health waste management program by 3 of the 4 units mentioned, under-notification and non-use of production billing codes before the Unified Health System (SUS), non-standard documents such as statistical reporting forms, control of supplies and permanent material. The problems identified by this study, as well as suggestions for the improvement, expansion and access democratization to dental prosthesis services offered to the population were brought to the attention of the Oral Health Coordination (CSB), which considered it´s demand answered. (AU)


Assuntos
Saúde Bucal , Prótese Dentária , Laboratórios Odontológicos/organização & administração , Política de Saúde
15.
RFO UPF ; 25(3): 429-435, 20201231. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1357826

RESUMO

Objetivo: avaliar, in vitro, a dureza superficial e profunda de dois tipos diferentes de resina composta, quandoem contato com o cimento de óxido de zinco e eugenol (IRM®). Métodos: foram selecionadas as resinasCharisma® e Vittra® e confeccionados 80 corpos de prova, sendo 40 para cada marca de compósito, queforam divididos em oito grupos (n=10) conforme o contato (imediato, 7 dias, 14 dias) ou não (grupo controle)com o eugenol. Colocou-se num pote dappen uma porção de IRM e um espécime de resina pronto, que,após a presa do material restaurador temporário e a remoção do exemplar colocado, gerou o molde pararealização das amostras em contato com o eugenol, sendo armazenado em água em temperatura ambiente,para os subgrupos 7 e 14 dias. Em sequência, foi inserido um único incremento de resina composta e polimerizadopor 40 segundos, gerando os espécimes que foram armazenados em local seco para serem submetidosao teste de microdureza Vickers sob uma carga de 300 gramas, com tempo de penetração de 10 segundos.Os dados obtidos foram analisados pelo teste ANOVA, a um nível de significância de p<0,05. Resultados:somente o grupo da resina Charisma® que teve contato imediato com eugenol não atingiu 80% de durezaprofunda em relação à superficial. Entretanto, para todos os grupos analisados, tanto a dureza superficialquanto a profunda aumentaram após o contato com o eugenol em relação ao grupo controle. Conclusão: oeugenol não influenciou negativamente a dureza das resinas compostas.(AU)


Objective: to evaluate, in vitro, the superficial and deep hardness of two different types of composite resin when in contact with zinc oxide eugenol cement (IRM). Method: Charisma® and Vittra® resins were selected and 80 specimens were made, 40 for each composite brand that were divided into eight groups (n = 10) according to contact (immediate, 7 days, 14 days) or no (control group) with eugenol. A portion of IRM and a ready-made resin specimen were placed in a dappen pot, which after setting the temporary restorative material and removing the placed specimen, generated the template for making the samples in contact with eugenol, being stored in water in room temperature for subgroups 7 and 14 days. In sequence, a single increment of composite was inserted and polymerized resin for 40 seconds, generating specimens that were stored in a dry place to be submitted to the Vickers microhardness test under a load of 300 grams, with a penetration time of 10 seconds. The data obtained were analyzed by the ANOVA test, at a significance level of p <0.05. Results: only the Charisma® resin group that had immediate contact with eugenol did not reach 80% deep hardness in relation to superficial hardness. However, for all groups analyzed, both superficial and deep hardness increased after contact with eugenol compared to the control group. Conclusion: eugenol did not negatively influence the hardness of composite resins.(AU)


Assuntos
Cimento de Óxido de Zinco e Eugenol/química , Resinas Compostas/química , Dureza , Valores de Referência , Propriedades de Superfície , Fatores de Tempo , Análise de Variância , Testes de Dureza
16.
Acta odontol. latinoam ; 33(2): 82-89, Sept. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1130737

RESUMO

ABSTRACT The aim of this study was to evaluate the degree of conversion, cytotoxicity, solubility and pH of photopolymerizable calciumbased cements submitted to preheating. The degree of conversion was analyzed by Fourier transform infrared, cytotoxicity by the MTT test and solubility through loss of mass. The data were subjected to statistical tests (ANOVA / Tukey's, p<0.05). The photopolymerizable materials showed a low degree of conversion, regardless of preheating. All materials caused a reduction in cell viability at 24 hours and 7 days, with the Dycal (control) being more cytotoxic. Heat had a positive effect on Biocal at 7 days. Dycal is the most soluble material. Heat had no effect on the solubility or pH of the polymerizable materials. It is concluded that photopolymerizable calcium-based cements have a low degree of conversion and are soluble, which results in mild to moderate cytotoxicity.


RESUMO O objetivo do presente estudo foi avaliar o grau de conversão, citotoxicidade, solubilidade e pH de cimentos à base de cálcio fotopolimerizáveis submetidos a pré-aquecimento. O grau de conversão foi analisado por espectroscopia no infravermelho com transformada de Fourier, a citotoxicidade pelo teste de MTT e a solubilidade através da perda de massa. Os dados foram submetidos a testes estatísticos (ANOVA/Tukey, p<0,05). Os materiais fotopolimerizáveis apresentaram baixo grau de conversão, independente do pré-aquecimento. Todos os materiais causaram redução da viabilidade celular nas análises de 24 horas e 7 dias, sendo que o Dycal (controle) apresentouse mais citotóxico e o calor apresentou efeito positivo sobre o Biocal na análise de 7 dias. O Dycal é o material mais solúvel e o calor não causou efeito na solubilidade e pH dos materiais polimerizáveis. Assim, conclui-se que os cimentos à base de cálcio fotopolimerizáveis apresentam baixo grau de conversão e são solúveis, que resulta em citotoxicidade suave e moderada.


Assuntos
Humanos , Hidróxido de Cálcio/toxicidade , Sobrevivência Celular/efeitos dos fármacos , Cimentos Dentários/química , Agentes de Capeamento da Polpa Dentária e Pulpectomia/toxicidade , Hidróxido de Cálcio/química , Cálcio , Cimentos Dentários/toxicidade , Capeamento da Polpa Dentária , Cura Luminosa de Adesivos Dentários , Processos Fotoquímicos , Agentes de Capeamento da Polpa Dentária e Pulpectomia/química , Polimerização , Concentração de Íons de Hidrogênio
17.
Acta odontol. latinoam ; 33(2): 98-103, Sept. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1130739

RESUMO

ABSTRACT The aim of the current study was to compare the effect of two lithium disilicate ceramic processing techniques (pressing and CAD/CAM) on the degree of conversion of resin cement when it is photoactivated and the microshear bond strength of resin cement to ceramics. Two ceramic discs were manufactured: one by the Press technique and another by CAD/CAM technique. Five Variolink Veneer resin cement samples were photoactivated through each ceramic disc and subjected to attenuated total reflectance Fourier transform infrared spectroscopy to evaluate their degree of conversion. To evaluate microshear bond strength, 20 ceramic bars were prepared: 10 using the Press technique and 10 using the CAD/CAM technique. The bars were air abraded with 50-μm Al2O3 particles, treated with 10% hydrofluoric acid for 20 s and subjected to RelyX Ceramic Primer application. Adper Scotchbond Multi-Purpose Adhesive was applied to the bars and cured for 10 s. Two 1-mm-height plastic tubes were placed on each bar and filled with Variolink Veneer resin cement. Each cylinder was cured for 20 s. Then the plastic tubes were removed and the microshear bond strength of each cylinder was tested. Data for degree of conversion (%) and microshear bond strength (MPa) were subjected to Student's t-test (α = 0.05). Both degree of conversion of resin cement photoactivated through ceramic and microshear bond strength of resin cement to ceramic were statistically higher in the group in which ceramic was prepared by CAD/CAM technique (44.74% and 22.18 MPa) than in the group in which the ceramic was prepared by the Press technique (25.71% and 19.83 MPa). The lithium disilicate ceramic processing techniques affected the degree of conversion of resin cement when it is photoactivated through the ceramics and the microshear bond strength of resin cement to ceramics.


RESUMO O objetivo do presente estudo foi comparar o efeito de duas técnicas de processamento da cerâmica de dissilicato de lítio (prensada e CAD/CAM) no grau de conversão do cimento resinoso quando fotoativado e na resistência de união ao microcisalhamento do cimento resinoso às cerâmicas. Foram fabricados dois discos de cerâmica: um pela técnica prensada e outro pela técnica CAD/CAM. Cinco amostras de cimento resinoso Variolink Veneer foram fotoativadas através de cada disco cerâmico e submetidas à espectroscopia no infravermelho por transformada de Fourier com reflectância total para avaliar seu grau de conversão. Para avaliar a resistência de união ao microcisalhamento, foram preparadas 20 barras de cerâmicas: 10 utilizando a técnica prensada e 10 utilizando a técnica CAD/CAM. As barras foram tratadas com partículas de Al2O3 (50 μm), com ácido fluorídrico a 10% por 20 s e submetidas à aplicação do RelyX Ceramic Primer. Em seguida, o adesivo multiuso Adper Scotchbond foi aplicado nas barras e fotoativado por 10 s. Dois tubos de plástico de 1 mm de comprimento foram colocados em cada barra e preenchidos com cimento resinoso Variolink Veneer. Cada cilindro foi fotoativado por 20 s. Os tubos de plástico foram removidos e a resistência de união ao microcisalhamento de cada cilindro foi testada. Os dados de grau de conversão (%) e resistência de união ao microcisalhamento (MPa) foram submetidos ao teste t de Student (α = 0,05). Tanto o grau de conversão do cimento resinoso fotoativado através da cerâmica quanto a resistência de união do cimento resinoso à cerâmica foram estatisticamente maiores no grupo em que a cerâmica foi confeccionada pela técnica CAD/CAM (44,74% e 22,18 MPa) do que no grupo em que a cerâmica foi confeccionada pela técnica prensada (25,71% e 19,83 MPa). As técnicas de processamento de cerâmica dissilicada de lítio afetaram o grau de conversão do cimento resinoso quando fotoativado através das cerâmicas e a resistência de união do microcisalhamento do cimento resinoso às cerâmicas.


Assuntos
Humanos , Cerâmica/química , Colagem Dentária , Cimentos de Resina/química , Porcelana Dentária/química , Propriedades de Superfície , Teste de Materiais
18.
Rev. Odontol. Araçatuba (Impr.) ; 41(2): 34-39, maio-ago.2020. tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1102682

RESUMO

As resinas Bulk fill surgiram com o intuito de facilitar a restauração de cavidades profundas. A fotoativação adequada é extremamente importante para que a resina bulk fill ofereça propriedades mecânicas satisfatórias e, longevidade na restauração. Este estudo avaliou a influência da espessura do incremento na microdureza Knoop (KHN) de três resinas bulk fill (n = 5). Cinquenta amostras foram divididas de acordo com o material (Filtek Z250, Filtek One Bulk Fill e Filtek Bulk Fill Flow), espessura (2mm e 4 mm) e tempo de fotoativação (20 e 40s) - Z2502mm20s, Z2502mm40s, One2mm20s, One2mm40s, One4mm20s, One4mm40s, Flow2mm20s, Flow2mm40s, Flow4mm20s e Flow4mm40s. As análises KHN foram realizadas no topo e na base de cada amostra. Os dados foram submetidos à ANOVA a 1 critério e ao Teste de Tukey (p< 0,05). A média e desvio padrão (+/-) dos seguintes grupos foram (Z2502mm20s) 0,85 (+/- 0,01); (Z2502mm40s) 0,92 (+/- 0,01); (One2mm20s) 1,05 (+/- 0,08); (One2mm40s) 0,95 (+/- 0,04); (One4mm20s) 0,93 (+/- 0,04); (One4mm40s) 0,97 (+/ - 0,04); (Flow2mm20s) 0,92 (+/- 0,05); (Flow2mm40s) 0,89 (+/- 0,04); (Flow4mm20s) 0,79 (+/- 0,04) e (Flow4mm40s) 0,90 (+/- 0,03). Os grupos da Filtek One Bulk apresentaram um valor significativamente maior, demonstrando uma polimerização suficiente mesmo na base de incrementos com 4 mm. Concluiu-se que o aumento na espessura do incremento de resinas bulk fill não afetou negativamente a fotoativação(AU)


Bulk fill composites emerged, allowing the restoration of deep cavities easily. Appropriate lightcuring is crucial to bulk fill composite presents satisfactory mechanical properties and restoration longevity. This study evaluated the influence of thickness increment on Knoop microhardness (KHN) of three dental bulk fill composites (n=5). Fifty samples were divided according to composite (Filtek Z250, Filtek One Bulk Fill and Filtek Bulk Fill Flow), thickness (2mm and 4 mm) and time lightcuring (20 and 40 s) - Z2502mm20s, Z2502mm40s, One2mm20s, One2mm40s, One4mm20s, One4mm40s, Flow2mm20s, Flow2mm40s, Flow4mm20s e Flow4mm40s. KHN analysis were performed on the top and the base of each specimen. Data were subjected to one-way ANOVA and Tukey test (p< 0,05). The mean and standard deviation (+/-) of following groups were (Z2502mm20s) 0,85(+/-0,01); (Z2502mm40s) 0,92(+/- 0,01); (One2mm20s) 1,05(+/-0,08); (One2mm40s) 0,95(+/-0,04); (One4mm20s) 0,93 (+/-0,04); (One4mm40s) 0,97(+/-0,04); (Flow2mm20s) 0,92(+/- 0,05); (Flow2mm40s) 0,89(+/-0,04); (Flow4mm20s) 0,79(+/-0,04) e (Flow4mm40s) 0,90(+/-0,03) Filtek One Bulk groups present significantly higher value, demonstrating sufficient polymerization even on the base of 4 mm increments. It was concluded that the increase in the thickness increment of Bulk fill composites did not negatively affect the lightcure(AU)


Assuntos
Resinas Compostas , Testes de Dureza , Materiais Dentários , Polimerização
19.
RFO UPF ; 25(1): 81-87, 20200430. tab, ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1357728

RESUMO

Introdução: a resina composta é um dos materiais restauradores mais pesquisados na Odontologia, visando melhorias nas suas propriedades e aperfeiçoamento da técnica. Este trabalho tem o objetivo de avaliar a rugosidade superficial de duas resinas compostas, micro-híbrida e nanoparticulada, após a polimerização adicional com micro-ondas. Materiais e métodos: para cada resina composta, foram confeccionados 24 corpos de prova, medindo 0,8 cm de diâmetro interno por 0,2 cm de espessura, dos quais, 12 receberam polimerização adicional com micro-ondas e 12, apenas a polimerização com luz azul visível. Foram estabelecidos quatro grupos: G1 - resina micro-híbrida submetida à polimerização convencional; G2 - resina nanoparticulada submetida à polimerização convencional; G3 - resina micro-híbrida exposta à polimerização adicional em forno de micro-ondas caseiro; e G4 - nanoparticulada exposta à polimerização adicional em forno de micro-ondas caseiro. Os corpos de prova foram lixados em politriz, com o intuito de uniformizar as superfícies, seguindo com leitura no rugosímetro digital Mitutoyo SJ 301. O teste não paramétrico Exato de Mann-Whitney (significância de 5%) foi realizado utilizando a média aritmética (Ra, µm). Conclusão: não houve significância estatística entre os tipos de polimerização e nem entre as diferentes resinas compostas estudadas.(AU)


Introduction: composite resin is one of the most researched restorative materials in dentistry, aiming to improve its properties and improve the technique. This work aims to evaluate the superficial rugosity of two composite resins, microhybrid and nanoparticulate, after additional polymerization with microwaves. Materials and methods: for each composite resin, 24 specimens were made, measuring 0.8cm internal diameter by 0.2cm thick, of which 12 received additional microwave polymerization and 12 visible-blue-light polymerization only. Four groups were established: G1 - microhybrid resin subjected to conventional polymerization; G2 - nanoparticulate resin subjected to conventional polymerization; G3 - microhybrid resin exposed to additional polymerization in a home microwave oven; and G4 - nanoparticulate exposed to additional polymerization in a home microwave oven. The specimens were sanded in a polishing machine in order to standardize the surfaces, followed by reading on the Mitutoyo SJ 301 digital roughness meter. The Mann-Whitney Exact nonparametric test (5% significance) was performed using the arithmetic mean (Ra, µm). Conclusion: there was no statistical significance between the polymerization types and neither among the different composite resins studied.(AU)


Assuntos
Resinas Compostas/química , Luzes de Cura Dentária , Polimerização , Micro-Ondas , Propriedades de Superfície , Teste de Materiais , Estatísticas não Paramétricas , Nanopartículas/química
20.
Braz. dent. sci ; 23(2): 1-10, 2020. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1096329

RESUMO

Objectives: This study aims to evaluate the degree of conversion (DC) and microlekage scores of three different composite resins polymerized with a LED curing device in standard and extra-power mode. Material and Methods: One bulk-fill (Tetric EvoCeram Bulk-Fill ­ TECBF) and two conventional composite materials (Clearfil Majesty Posterior ­ CMP and Tetric EvoCeram ­ TEC) were evaluated. A total of 30 specimens were prepared for six groups (N = 5). These groups were polymerized with a LED curing device as follows: TECBF-6: 3200mW/cm2 for six seconds, TECBF-20: 1000mW/cm2 for 20 seconds, CMP-6: 3200mW/cm2 for six seconds, CMP-20: 1000mW/cm2 for 20 seconds, TEC-6: 3200mW/cm2 for six seconds, TEC - 20: 1000 mW/cm2 for 20 seconds. After 24 hours of water storage, DC was measured by Raman spectroscopy. Microleakage scores of the six groups were bonded to various adhesive systems (Clearfil SE Bond or Adhese Bond Universal) were also evaluated at Class II box cavities (N = 10). Results: While the highest DC was found at the top (TECBF-20= 79.92% and TECBF-6= 79.02%) and bottom surfaces (TECBF-20 = 68.94% and TECBF-6= 71.04%) for TECBF groups, TEC groups (TEC-20top = 59.06%, TEC-6top=49.66%, TEC-20bottom = 43.72% and TEC-6bottom= 40.68%) showed the lowest DC for the both surfaces (p < 0.05). Polymerization of materials in standard or extra-power mode was similar to DC (p > 0.05). Microleakage scores were found to be similar (p > 0.05). Conclusion: According to the results of the study, different power densities of LED curing light did not affect the DC of composite resins and microleakage values of restorations at small Class II cavities (AU)


Objetivo: este estudo tem como objetivo avaliar os graus de conversão (DC) e microinfiltração de três diferentes resinas compostas polimerizáveis com um dispositivo de luz por LED nos modos padrão e no modo de alta-potência. Material e métodos: uma resina bulk-fill (Tetric EvoCeram Bulk-Fill - TECBF) e dois materiais resinosos convencionais (Clearfil Majesty Posterior - CMP e Tetric EvoCeram - TEC) foram avaliados. Um total de 30 espécimes foram preparados e divididos em seis grupos (N = 5). Esses grupos foram polimerizados com um dispositivo de luz de LED da seguinte forma: TECBF-6: 3200mW / cm2 por seis segundos, TECBF-20: 1000mW / cm2 por 20 segundos, CMP-6: 3200mW / cm2 por seis segundos, CMP20: 1000mW / cm2 por 20 segundos, TEC-6: 3200mW / cm2 por seis segundos, TEC - 20: 1000 mW / cm2 por 20 segundos. Após 24 horas de armazenamento em água, a DC foi medida por espectroscopia Raman. Os escores de microinfiltração dos seis grupos dos vários sistemas adesivos (Clearfil SE Bond ou Adhese Bond Universal) também foram avaliados nas cavidades Classe II (N = 10). Resultados: embora a maior CD tenha sido encontrada nas partes superior (TECBF-20 = 79,92% e TECBF-6 = 79,02%) e inferiores (TECBF-20 = 68,94% e TECBF-6 = 71,04%) para grupos TECBF, os grupos TEC (TEC-20top = 59,06%, TEC-6top = 49,66%, TEC-20bottom = 43,72% e TEC-6bottom = 40,68%) apresentaram as menores CD para as ambas as partes (p < 0,05). A polimerização de materiais no modo padrão ou alta-potência foi semelhante à DC (p > 0,05). Os escores de microinfiltração foram semelhantes (p > 0,05). Conclusão: de acordo com os resultados do estudo, diferentes densidades de potência da luz de LED não afetaram as CD das resinas compostas e os valores de microinfiltração das restaurações em pequenas cavidades da Classe II. (AU)


Assuntos
Análise Espectral Raman , Adesivos Dentinários , Resinas Compostas , Infiltração Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...